Huawei H19-105_V2.0 Exam Syllabus Topics:

Section Objectives
Topic 1: Cooling and Environmental Control - Cooling Technologies
  • 1. Precision air conditioning concepts
    • 2. Heat management in data centers
      Topic 2: Data Center Facility Fundamentals - Overview of Data Center Infrastructure
      • 1. Roles and components of facility systems
        • 2. Basic concepts of data centers
          - Power Systems Overview
          • 1. UPS systems and backup power
            • 2. Power distribution principles
              Topic 3: Huawei Data Center Solutions Overview - Huawei facility product portfolio
              • 1. Smart management systems
                • 2. Modular data center solutions
                  Topic 4: Sales and Solution Positioning - Customer requirements analysis
                  • 1. Typical industry scenarios
                    • 2. Solution matching principles

                      >> Huawei H19-105_V2.0 100%시험패스 덤프문제 <<

                      H19-105_V2.0시험대비 최신 덤프공부자료 - H19-105_V2.0시험대비 최신버전 자료

                      Itcertkr에서는 전문Huawei H19-105_V2.0인증시험을 겨냥한 덤프 즉 문제와 답을 제공합니다.여러분이 처음Huawei H19-105_V2.0인증시험준비라면 아주 좋은 덤프입니다. Itcertkr에서 제공되는 덤프는 모두 실제시험과 아주 유사한 덤프들입니다.Huawei H19-105_V2.0인증시험패스는 보장합니다. 만약 떨어지셨다면 우리는 덤프비용전액을 환불해드립니다.

                      최신 Huawei Data Center Facility H19-105_V2.0 무료샘플문제 (Q21-Q26):

                      질문 # 21
                      For a JMF (Joint Marketing Fund) activity, third-party invoices are not required to be submitted when the activity is classified as a non-standard activity.

                      • A. True
                      • B. False

                      정답:B

                      설명:
                      Huawei Digital Power's Joint Marketing Fund (JMF) is a structured channel incentive designed to support partner-led marketing initiatives, strengthen brand positioning, and generate measurable business opportunities. The JMF management process incorporates activity planning, prior authorization, execution, acceptance, and financial settlement to maintain control over the use of marketing funds.
                      The critical distinction concerns whether classification as a non-standard activity automatically removes the requirement to provide financial supporting documents. Classification alone does not establish an exemption from the JMF approval and acceptance process. Third-party invoices may serve as evidence of actual expenditure, supplier engagement, and the legitimacy of marketing costs. Their submission requirements must nevertheless be determined by the applicable activity category and regional acceptance rules.
                      Option B is the more defensible selection because the statement assumes an unconditional exemption without establishing the governing documentation criteria. However, the JMF course section specifies activity approval, acceptance, and claiming requirements rather than a definitive invoice-submission rule for non- standard activities.
                      Consequently, the invoice-specific answer remains provisional until the relevant JMF reimbursement or acceptance documentation is established.
                      Huawei Training Material - Supporting Extract
                      JMF Activity Application and Acceptance: Partner develop the activity plan and submit the activity application. Planning shall be carried out in advance and execution shall be performed after approval. In principle, an activity application shall be submitted at least seven working days before the actual start date of the activity. JMF activities which have not been approved in advance will not receive payments.
                      JMF Claim: The JMF amount cannot be directly transferred or cashed. JMF can be claimed after activity acceptance.
                      The course does not define an invoice exemption for non-standard JMF activities.
                      Huawei Course Reference: Introduction to Data Center Facility Partner Policies Outside China - JMF Introduction; JMF Activity Application and Acceptance; JMF Claim. PDF page 90; slide 10.
                      Verification assessment: Invoice-specific evidence not established in the course; answer provisional.


                      질문 # 22
                      Which of the following statements about the Huawei high-temperature chilled water fan wall are correct?
                      Select all that apply

                      • A. Key components, such as the main control unit, fan drive unit, low-voltage power supply unit, and fan unit, adopt the modular design and support hot swapping and quick maintenance within 1 minute.
                      • B. The DG integrates the PFC module, which reduces the harmonic wave and ensures the safety of the power supply link without the need for APF.
                      • C. Compared with traditional downflow chilled water terminals, no raised floor is required, greatly reducing cooling investment.
                      • D. Compared with traditional room-level chilled water, the inlet water temperature increases from 15°C to
                        20°C, reducing the CLF by 15%.

                      정답:B,C,D

                      설명:
                      Huawei's high-temperature chilled water fan-wall solution combines electrical efficiency, modular maintenance, simplified infrastructure construction, and improved cooling performance.
                      Option A describes the solution's integrated Power Factor Correction (PFC) capability. Huawei's intelligent rectifier incorporates PFC technology, reducing Total Harmonic Distortion of current (THDi) to below 5% and improving power factor to above 0.99 under the stated rated-load conditions. This eliminates the requirement for a separate Active Power Filter (APF) for the specified harmonic performance. However, the term DG is not established as the component integrating PFC; the identified component is the intelligent rectifier.
                      Option C is correct because the fan-wall solution uses horizontal airflow distribution without requiring raised- floor construction. Removing the raised-floor requirement simplifies installation and reduces associated capital expenditure.
                      Option D is correct because the higher chilled-water inlet temperature, increasing from approximately 15°C to
                      20°C, improves cooling efficiency and reduces Cooling Load Factor (CLF) by approximately 15%.
                      Option B introduces an unsupported extension of the hot-swappable component list. The modular hot-swap design specifically identifies the main control board, fan driver, and low-voltage power supply. The complete fan unit is not expressly included in that one-minute hot-swap list.
                      Therefore, A, C, and D are the intended selections, with the component terminology in A requiring correction.
                      Huawei Training Material - Supporting Extract
                      Fan Wall High-Efficiency Cooling: 15%# CLF; inlet water temperature:15 # # 20 # ; Simplified O & M: 1min (30min # 1min); Hot-swappable module.
                      Integrated PFC module, THDi < 5%, PF > 0.99 @100% load. Intelligent rectifier (integrates PFC). THDi <
                      5%@100% load, APF is not required.
                      Huawei modular design (main control board/fan driver/and low-voltage power supply).
                      Huawei Course Reference: Fan Wall: High-Efficiency Cooling, Extraordinary Reliability, and Simplified O
                      & M; Integrated PFC Module; One-Side Maintenance. PDF pages 36-39; slides 37-40.


                      질문 # 23
                      The cooling unit in the FusionModule800 employs energy-saving humidification technology to help lower PUE. Which humidification solution does the Huawei FusionModule800 use?

                      • A. Wet film humidification
                      • B. Ultrasonic humidification
                      • C. Infrared humidification
                      • D. Electrode humidification

                      정답:A

                      설명:
                      Huawei FusionModule800 employs wet-film humidification to maintain appropriate environmental conditions while minimizing energy consumption associated with humidity control.
                      Wet-film humidification is based on evaporative moisture transfer. Water is distributed over a wetted medium, and air passing across that medium absorbs moisture through evaporation. Unlike steam-based humidification systems, this process does not require substantial electrical energy to heat water to its boiling point.
                      This characteristic makes wet-film humidification particularly suitable for energy-efficient data center cooling systems, where auxiliary electrical loads contribute directly to Power Usage Effectiveness (PUE).
                      Huawei integrates this technology with aisle containment and hot/cold airflow separation to improve cooling efficiency and reduce unnecessary energy consumption.
                      The solution's stated humidification energy reduction is approximately 95% compared with the conventional approach used in the product comparison.
                      Option A, infrared humidification, relies on electrically generated heat to produce moisture. Option C, electrode humidification, similarly uses electrical current to generate steam. Option D, ultrasonic humidification, atomizes water through high-frequency vibration but is not the specified FusionModule800 solution.
                      Option B is therefore correct because wet-film humidification is the designated energy-saving humidification technology for the relevant FusionModule800 architecture.
                      Huawei Training Material - Supporting Extract
                      Aisle containment and wet film Humidification.
                      Cold and hot isolation, improving cooling efficiency.
                      Wet film, reducing humidification energy consumption by 95%.
                      The integrated design achieves simplified deployment and efficient edge data center operation.
                      Huawei Course Reference: Introduction to Huawei Data Center Facility and Critical Power Solutions - FusionModule800 & 500: Integrated Design to Build Simplified Edge DC. PDF page 54; slide 55.


                      질문 # 24
                      In the fan wall solution, which of the following components support hot-swap maintenance?
                      Select all that apply

                      • A. Main control module
                      • B. Power module
                      • C. EC fan
                      • D. Fan drive module

                      정답:A,D

                      설명:
                      Huawei's high-temperature chilled water fan-wall solution incorporates modular serviceable electronic components to minimize cooling interruptions and reduce maintenance effort.
                      Option B is correct because the main control module forms part of Huawei's modular controller architecture.
                      It supports replacement through a plug-in design, simplifying maintenance compared with traditional fixed electrical control arrangements.
                      Option C is correct because the fan drive module supports hot-swappable maintenance. Separating the drive from the fan enables technicians to replace faulty drive electronics without shutting down the complete cooling unit under the supported maintenance procedure.
                      This capability is particularly important in high-density data centers, where cooling interruption may quickly increase IT equipment temperatures and compromise service availability.
                      Option A refers to the EC fan assembly itself. Although the fan is maintainable, the course distinguishes fan maintenance from the explicitly identified hot-swappable electronic modules. It does not establish that the entire EC fan assembly supports the same one-minute hot-swap operation.
                      Option D is ambiguously worded. The modular architecture includes a low-voltage power supply, but the question says power module. Without identifying that component as the low-voltage power supply unit, the terminology is insufficiently precise.
                      The intended two selections are B and C, corresponding to the named main control and fan drive modules.
                      The wording of D should be clarified before the question is treated as fully unambiguous.
                      Huawei Training Material - Supporting Extract
                      One-side maintenance, footprint reduced by 10%; Modular design, 1-minute hot-swappable maintenance.
                      Modular design and plug-in online maintenance.
                      Huawei modular design (main control board/fan driver/and low-voltage power supply).
                      Hot-swappable maintenance, which takes less than 1 minute.
                      The unit does not need to be shut down during maintenance, and the temperature of the equipment room does not fluctuate.
                      Huawei Course Reference: Fan Wall - One-Side Maintenance, Modular Design and Plug-In Online Maintenance. PDF page 38; slide 39.
                      Verification assessment: Main control and fan drive explicitly in hot-swap group; generic 'power module' is ambiguous.


                      질문 # 25
                      When an Energy Storage System (ESS) fire alarm activates but only smoke - not flame - is being emitted, which of the following is the correct response action?

                      • A. Approach the ESS to measure its temperature with your hand.
                      • B. Open the cabinet door, check the point of origin inside, and use a fire extinguisher to put out the fire.
                      • C. Open the valve for the water sprinkler pipe and start the water pump to inject water into the faulty ESS.
                      • D. Keep observing the situation remotely. Do not spray water into it for the time being, and pour water onto its surface to cool the temperature. Spray water into it after seeing open flame.

                      정답:D

                      설명:
                      Smoke emission from an Energy Storage System (ESS) indicates a potentially hazardous battery condition involving overheating, internal electrical faults, or the initial development of thermal runaway. Immediate response must prioritize personnel safety, remote observation, and controlled emergency procedures.
                      Option B is the closest answer because it emphasizes maintaining remote observation and avoiding the immediate introduction of water into an ESS emitting smoke without visible flames.
                      However, personnel must not interpret this option as authorization to approach a smoking cabinet to apply water externally. Huawei's fire safety requirements explicitly prohibit approaching a smoking ESS to spray water because electrical faults and sparks may ignite combustible gases accumulated inside the enclosure.
                      The appropriate initial response involves evacuating personnel, raising emergency alarms, maintaining a safe distance, and remotely isolating the equipment where possible.
                      If visible fire develops, appropriately equipped emergency responders should implement the approved fire- extinguishing and cooling procedures in accordance with local fire authority requirements and site conditions.
                      Option A is unsafe because opening the enclosure may introduce oxygen and increase explosion risk. Option C describes an intervention that is not appropriate as an automatic initial response to smoke alone. Option D exposes personnel directly to thermal, electrical, and explosion hazards.
                      Huawei Training Material - Supporting Extract
                      Fire Handling Process: Quickly evacuate personnel. Call the fire department. Try to remotely shut down the equipment. Continuously monitor the equipment in a safe area. Take personal protection measures.
                      Precautions for Handling Fire: Do not approach an ESS that emits smoke and spray water on it; combustible gas accumulation and electrical sparks may cause explosion. The specific fire handling process must be formulated according to local fire department requirements and onsite conditions.
                      Huawei Course Reference: Safety Management - Fire Handling Process; Precautions for Handling Fire.
                      PDF pages 183-184; slides 56-57.


                      질문 # 26
                      ......

                      H19-105_V2.0인증시험패스는 쉬운 일은 아닙니다. 높은 전문지식은 필수입니다.하지만 자신은 이 방면 지식이 없다면 Itcertkr가 도움을 드릴 수 있습니다. Itcertkr의 전문가들이 자기만의 지식과 지금까지의 경험으로 최고의 IT인증관련자료를 만들어 여러분들의 고민을 해결해드릴 수 있습니다. 우리는 최고의H19-105_V2.0인증시험문제와 답을 제공합니다. Itcertkr는 최선을 다하여 여러분이 한번에H19-105_V2.0인증시험을 패스하도록 도와드릴 것입니다. 여러분은 우리 Itcertkr 선택함으로 일석이조의 이익을 누릴 수 있습니다. 첫쨰는 관여지식은 아주 알차게 공부하실 수 있습니다.둘째는 바로 시험을 안전하게 한번에 통과하실 수 있다는 거죠.그리고 우리는 일년무료 업데이트서비스를 제공합니다.덤프가 업뎃이되면 우리는 모두 무료로 보내드립니다.만약 시험에서 실패한다면 우리 또한 덤프비용전액을 환불해 드립니다.